Eberle Instat 6 User Manual English May 2026

Last Updated: May 2026 Product Focus: Eberle Instat 6 Electronic Room Thermostat

| Code | Meaning | Solution | |------|---------|----------| | E1 | Internal sensor fault (open circuit) | Replace thermostat or sensor | | E2 | Internal sensor short circuit | Check for moisture/damage – replace unit | | E5 | External sensor fault (optional) | Check external sensor wiring or disable in P## | | Battery icon flashing | Backup battery low (clock will reset on power loss) | Replace CR2032 battery on PCB (requires opening unit) | | Flame symbol on but room cold | Relay stuck or wiring issue | Check voltage at terminal 2. If 0V, thermostat faulty. If 230V, boiler problem. | | Display blank | No power or internal fuse blown | Check circuit breaker, then test L-N voltage. | eberle instat 6 user manual english

A: Set P02 to a lower cycle time (e.g., 5 minutes) and ensure the thermostat is not near drafts or sunlight. Last Updated: May 2026 Product Focus: Eberle Instat

The Eberle Instat 6 uses screw terminals on the rear. Ensure correct wire gauge (0.5-2.5 mm² solid or stranded). | | Display blank | No power or

Use Up/Down to select PXX, press Clock, adjust value with Up/Down, press Clock to save. Exit by holding Auto/Manual for 3 seconds. 8. Wiring Diagram and Terminal Assignments Danger: 230V AC present. Only for qualified installers.

| Terminal | Label | Description | |----------|-------|-------------| | N | Neutral (mains input) | 230V AC neutral | | L | Live (mains input) | 230V AC live | | 1 | Common (COM) | Relay common contact | | 2 | Normally Open (NO) | Relay NO – closes on heat call | | 3 | Normally Closed (NC) | Not used in most heating systems | | (S1, S2) | External sensor | Optional floor sensor (if equipped) |